Choose K2-40 when the part fits the -40 envelope, two indicator positions are needed, and the second measurement requires vertical access.
K2-40 Dual Indicator Concentricity Gage
Two configurable measurement positions for larger cylindrical components.
The Universal Punch K2-40 expands the K2 dual-indicator architecture to cylindrical components from 3/4–4 in (20–102 mm nominal) in diameter and up to 8 in (203 mm) long.
Its defining architecture combines a Standard Carrier with a Vertical Carrier, creating two configurable indicator positions around one supported rotating component.
Choose K2-40 when the application requires the -40 component envelope, two indicator positions, and vertical access for the second measurement.
K2 architecture with the large -40 inspection envelope.
K2 identifies Universal Punch's dual-indicator Standard Carrier + Vertical Carrier architecture.
-40 identifies the large component class used for nominal 3/4–4 in cylindrical parts and part lengths up to 8 in / 203 mm.
Is K2-40 the right concentricity gage for your application?
First confirm the larger -40 component envelope. Then select the carrier architecture from the number and direction of measurement positions required by the print.
Use the same large -40 capacity class when the second indicator needs lateral Side Carrier access.
Choose G2-40 when one Vertical Carrier inspection position is sufficient.
Choose KK2-40 when the large component requires three independently configurable measurement positions.
Two measurement positions. One supported rotational setup.
K2-40 combines a Standard Carrier measurement position with a second Vertical Carrier measurement position around the same large-capacity support system.
Standard Carrier
Establishes the primary configurable indicator position. Determine contact location, range, resolution, stylus and approach from the drawing and inspection plan.
Vertical Carrier
Provides the vertical-access measurement position that defines the K2 family. Use it when the second inspection feature benefits from a vertical probe approach.
Configure the first measurement position from the component drawing.
The Standard Carrier establishes the primary K2-40 indicator position. Final setup should reflect the actual inspection feature, datum relationship and available component clearance.
Vertical Carrier access separates K2-40 from K1-40.
The second K2-40 measurement position uses a Vertical Carrier, creating a vertically oriented probe location relative to the supported component.
Because K1-40 and K2-40 serve essentially the same large-capacity size class, the direction of second-indicator access is the primary architectural distinction.
K2-40 specifications and large-capacity envelope.
Use published capacity as an initial model-selection reference. Confirm actual support geometry, metric capacity, indicators, calibration and drive configuration when quoting.
| Specification | K2-40 Published / Current Reference |
|---|---|
| Model | K2-40 |
| Gage Type | Dual Indicator Concentricity Gage |
| Carrier Configuration | Standard Carrier + Vertical Carrier |
| Nominal Part Diameter | 3/4–4 in |
| Customer-Facing Metric Range | 20–102 mm |
| Current Parts-List Metric Class Reference | 20–105 mm |
| Maximum Part Length | 8 in / 203 mm |
| Approx. Overall Gage Length | 14.5 in / 368 mm |
| Approx. Gage Width | 8 in / 203 mm |
| Approx. Gage Height | 8 in / 203 mm |
| Published Shipping Weight | 18.5 lb / 8.4 kg |
Select support geometry from the actual component.
Both K2-40 indicators reference the same supported rotational setup. Correct -40 roller and top-contact selection is therefore fundamental to the complete inspection system.
Evaluate cylindrical support-land width, adjacent shoulders, flange clearance, grooves, threads, splines, diameter transitions, support spacing, unsupported span, component stiffness and both indicator measurement locations.
Confirm. Support. Position. Rotate. Interpret.
K2-40 belongs to the Standard Black -40 accuracy class.
Current Universal Punch documentation identifies Precision Gold for applicable -10 and -20 models only. K2-40 is a -40 model and should therefore be represented under the published Standard Black classification unless a different current production capability is specifically confirmed.
Final measurement performance depends on the exact gage configuration, support geometry, indicator selection, inspection method and calibration documentation.
Configure each K2-40 measurement position independently.
The two indicators do not have to perform identical measurement roles. Each measurement position should be selected around its required feature, range, resolution, stylus and access direction.
Select rotational control around the inspection workflow.
Manual Rotation
Universal Punch literature describes a manual timing-belt pulley system for smooth, controlled rotational inspection.
Main rollers, top contact, rotation, Standard Carrier and Vertical Carrier positions work together as one complete K2-40 inspection configuration.
K2-40 Variable Speed Motor Assembly
Universal Punch publishes 278-40 as the K2-40 Variable Speed Motor Assembly with a published 19 in / 482 mm base plate.
Current motor-drive documentation identifies a 24 VDC · 0–10 rpm · variable-speed · forward/reverse architecture. Confirm transformer, foot-switch and current electrical accessories when quoting.
Ask About Motorizing the K2-40 →Choose the large-capacity model from measurement access.
K2-40 vs. K1-40
| Feature | K2-40 | K1-40 |
|---|---|---|
| Indicator Positions | 2 | 2 |
| Nominal Part Diameter | 3/4–4 in | 3/4–4 in |
| Maximum Part Length | 8 in / 203 mm | 8 in / 203 mm |
| Primary Carrier | Standard | Standard |
| Second Carrier | Vertical Carrier | Side Carrier |
| Published Shipping Weight | 18.5 lb / 8.4 kg | 18.5 lb / 8.4 kg |
K2-40 vs. G2-40
Dual Indicator
Standard Carrier + Vertical Carrier
Two configurable measurement positions around one large-capacity supported rotational setup.
Vertical Carrier Architecture
One vertical-access measurement architecture
Choose when one Vertical Carrier inspection position is sufficient.
View G2-40 →K2-40 vs. KK2-40
2 Measurement Positions
Standard Carrier + Vertical Carrier.
Choose when Standard and Vertical access satisfy the inspection plan.
3 Measurement Positions
Standard Carrier + Side Carrier + Vertical Carrier.
Choose when the large component additionally requires an independent Side Carrier position.
View KK2-40 →K2-Series Capacity Progression
| Model | Part Diameter | Maximum Part Length | Architecture |
|---|---|---|---|
| K2-10 | 1/8–1 in / 3–25 mm | 4 in / 102 mm | Standard + Vertical Carrier |
| K2-20 | 3/8–2 in / 10–50 mm | 6 in / 152 mm | Standard + Vertical Carrier |
| K2-40 | 3/4–4 in / 20–102 mm nominal | 8 in / 203 mm | Standard + Vertical Carrier |
Configure K2-40 around the complete inspection requirement.
The K2-40 is a configurable inspection system. Final application depends on gage selection, support geometry, both indicator positions, accuracy and calibration requirements, and rotational method.
Common engineering questions about the K2-40.
What is the Universal Punch K2-40?
The Universal Punch K2-40 is a large-capacity dual-indicator concentricity gage for cylindrical components from 3/4–4 in (20–102 mm nominal customer-facing range) in diameter and up to 8 in (203 mm) long. It combines a Standard Carrier with a Vertical Carrier so two configurable indicator positions can be arranged around one supported rotational setup.
What does K2-40 mean?
K2 identifies the Universal Punch dual-indicator architecture using a Standard Carrier plus Vertical Carrier. The -40 suffix identifies the large component class used for nominal 3/4–4 in cylindrical parts.
What size parts can the K2-40 inspect?
The customer-facing nominal K2-40 range is 3/4–4 in (approximately 20–102 mm) in diameter with part lengths up to 8 in (203 mm). Current parts documentation also references the -40 metric class as 20–105 mm. Confirm the actual component diameter and current production capability when quoting.
Why are both 20–102 mm and 20–105 mm associated with K2-40?
The nominal 3/4–4 in customer-facing range converts to approximately 20–102 mm, while current Universal Punch parts documentation uses a 20–105 mm metric class reference for the -40 platform. Both refer to the large -40 model family. Confirm the exact production envelope for the application when quoting.
What are the published overall dimensions of the K2-40?
Published K1/K2-40 general data lists approximately 14.5 in (368 mm) overall length, 8 in (203 mm) width and approximately 8 in (203 mm) height.
How much does the K2-40 weigh?
The published K2-40 shipping weight is 18.5 lb (8.4 kg).
Why does the K2-40 use two indicators?
K2-40 provides two configurable measurement-access positions around the same supported rotational setup. The first uses a Standard Carrier and the second uses a Vertical Carrier. What each indicator evaluates depends on the drawing, support geometry, datum structure and inspection method.
What is the difference between K2-40 and K1-40?
K2-40 and K1-40 share the large -40 capacity class and both use two indicator positions. K2-40 uses Standard plus Vertical Carrier architecture, while K1-40 uses Standard plus Side Carrier architecture. Select between them primarily by the required direction of the second indicator.
What is the difference between K2-40 and G2-40?
G2-40 uses a Vertical Carrier inspection architecture. K2-40 adds a Standard Carrier measurement position so two indicator positions can be configured around the same supported rotational setup.
What is the difference between K2-40 and KK2-40?
K2-40 uses Standard plus Vertical Carrier architecture for two measurement positions. KK2-40 adds an independent Side Carrier position, creating Standard plus Side plus Vertical Carrier measurement access.
What main roller configurations are published for K2-40?
Universal Punch publishes Full Plain 140-40FP, Half Plain 140-40HP and Quarter Plain 140-40QP main roller configurations for the -40 model class. Final support geometry should be selected from the actual usable cylindrical support lands on the component.
What is the standard -40 top roller?
Universal Punch documentation identifies 230-40, approximately 1 × 5/16 in (25 × 8 mm), as the standard -40 top roller. Other -40 top roller sizes are also published. Confirm final top-contact geometry against the actual component.
Is K2-40 a Precision Gold gage?
Current Universal Punch documentation identifies Precision Gold for applicable -10 and -20 model classes only. K2-40 is a -40 model and should therefore be represented under the Standard Black classification unless a different current production capability is specifically confirmed by Universal Punch.
What accuracy classification applies to K2-40?
Universal Punch publishes Standard Black at better than or equal to 4 µm (0.00016 in). Final performance and calibration documentation should be confirmed for the exact ordered K2-40 configuration.
Is the K2-40 NIST traceable?
Universal Punch documentation states that its Concentricity Gaging Systems are calibrated and directly traceable to N.I.S.T. Confirm the calibration certificate and documentation required for the ordered configuration.
Can the K2-40 be motorized?
Yes. Universal Punch publishes Part No. 278-40 as the K2-40 Variable Speed Motor Assembly with a published 19 in (482 mm) base plate. Confirm current electrical accessories and options when quoting.
What information should I send Universal Punch for a K2-40 quote?
Send the component drawing, maximum part diameter and length, usable support journals, support-land widths, shoulders, flanges, threads, splines or grooves, both measurement locations, required vertical access, datum relationship, tolerance, desired indicator resolution, calibration requirements and manual or motorized preference.
Send the drawing and both measurement locations.
Universal Punch can review the component geometry and inspection requirement to help determine K2-40 support geometry, Standard Carrier position, Vertical Carrier position, indicators, calibration documentation and rotational configuration.
- component drawing or CAD print
- maximum part diameter
- overall part length
- support-journal diameters
- support-land widths
- shoulders and flanges
- threads, splines and grooves
- measurement location #1
- measurement location #2
- required vertical indicator access
- datum relationship
- inspection tolerance
- indicator resolution
- calibration requirements
- manual or motorized preference
- production inspection volume
Compare K1-40, G2-40, KK2-40, and K2-20 when selecting measurement access and component capacity.