Universal Punch Concentricity Gaging System K2 Series · -40 Dual Indicator · Standard + Vertical Carrier

K2-40 Dual Indicator Concentricity Gage

Two configurable measurement positions for larger cylindrical components.

The Universal Punch K2-40 expands the K2 dual-indicator architecture to cylindrical components from 3/4–4 in (20–102 mm nominal) in diameter and up to 8 in (203 mm) long.

Its defining architecture combines a Standard Carrier with a Vertical Carrier, creating two configurable indicator positions around one supported rotating component.

Choose K2-40 when the application requires the -40 component envelope, two indicator positions, and vertical access for the second measurement.

Universal Punch K2-40 large capacity dual indicator concentricity gage with Standard Carrier and Vertical Carrier
K2-40 · Dual Indicator Gage. Standard Carrier + Vertical Carrier architecture on the large -40 platform.
3/4–4 in 20–102 mm nominal customer-facing diameter
Up to 8 in 203 mm maximum part length
2 Indicators Standard + Vertical Carrier
18.5 lb 8.4 kg published shipping weight
Technical page last updated: September 1, 2026. Confirm current production configuration when quoting.
K2-40 Definition

K2 architecture with the large -40 inspection envelope.

K2 identifies Universal Punch's dual-indicator Standard Carrier + Vertical Carrier architecture.

-40 identifies the large component class used for nominal 3/4–4 in cylindrical parts and part lengths up to 8 in / 203 mm.

The Universal Punch K2-40 is a large-capacity dual-indicator concentricity gage using Standard Carrier + Vertical Carrier measurement access around one supported rotational setup.
Metric-capacity documentation note: Universal Punch documentation consistently identifies K2-40 as the large -40 model class. Current parts documentation uses a 20–105 mm metric reference, while the nominal 3/4–4 in customer-facing envelope converts to approximately 20–102 mm. Confirm the actual component diameter and current production capability when quoting.
Full product view of Universal Punch K2-40 large capacity dual indicator concentricity gage
K2-40 architecture: large -40 support capacity with Standard Carrier and Vertical Carrier measurement access.
Application Decision Guide

Is K2-40 the right concentricity gage for your application?

First confirm the larger -40 component envelope. Then select the carrier architecture from the number and direction of measurement positions required by the print.

Choose K2-40 Standard + Vertical Carrier

Choose K2-40 when the part fits the -40 envelope, two indicator positions are needed, and the second measurement requires vertical access.

Choose K1-40 Standard + Side Carrier

Use the same large -40 capacity class when the second indicator needs lateral Side Carrier access.

Compare K1-40 →

Choose G2-40 Vertical Carrier architecture

Choose G2-40 when one Vertical Carrier inspection position is sufficient.

Compare G2-40 →

Choose KK2-40 Standard + Side + Vertical

Choose KK2-40 when the large component requires three independently configurable measurement positions.

Compare KK2-40 →

Dual-Indicator Architecture

Two measurement positions. One supported rotational setup.

K2-40 combines a Standard Carrier measurement position with a second Vertical Carrier measurement position around the same large-capacity support system.

Measurement Position 1

Standard Carrier

Establishes the primary configurable indicator position. Determine contact location, range, resolution, stylus and approach from the drawing and inspection plan.

Measurement Position 2

Vertical Carrier

Provides the vertical-access measurement position that defines the K2 family. Use it when the second inspection feature benefits from a vertical probe approach.

The defining capability of K2-40 is not merely two indicators. It is Standard Carrier + Vertical Carrier measurement access on the large -40 support platform.
Standard Carrier

Configure the first measurement position from the component drawing.

The Standard Carrier establishes the primary K2-40 indicator position. Final setup should reflect the actual inspection feature, datum relationship and available component clearance.

Inspection feature Identify the journal, diameter, face, shoulder or other feature being evaluated.
Datum relationship Define what the indicator response represents relative to the supported rotational axis.
Probe clearance Account for larger shoulders, flanges, grooves, threads, splines and diameter transitions.
Indicator selection Choose range, resolution, stylus reach and contact direction from the actual tolerance.
Configuration principle: K2-40 product photography shows example indicator positioning. Final Standard Carrier setup should be based on the actual drawing and inspection requirement.
K2-40 Standard Carrier primary indicator measurement position detail
K2-40 Standard Carrier detail. Configure the primary measurement position from the actual component and print.
K2-40 Vertical Carrier second indicator measurement position detail
K2-40 Vertical Carrier detail. Vertical access for the second measurement position defines the K2 architecture.
Vertical Carrier Architecture

Vertical Carrier access separates K2-40 from K1-40.

The second K2-40 measurement position uses a Vertical Carrier, creating a vertically oriented probe location relative to the supported component.

Choose K2-40 when the second measurement requires Vertical Carrier access. Choose K1-40 when the second measurement requires Side Carrier access.

Because K1-40 and K2-40 serve essentially the same large-capacity size class, the direction of second-indicator access is the primary architectural distinction.

Published K2-40 General Data

K2-40 specifications and large-capacity envelope.

Use published capacity as an initial model-selection reference. Confirm actual support geometry, metric capacity, indicators, calibration and drive configuration when quoting.

Nominal Part Diameter 3/4–4 in 20–102 mm customer-facing
Part Length Up to 8 in 203 mm
Carrier Architecture Standard + Vertical Dual indicator
Overall Length 14.5 in 368 mm
Width / Approx. Height 8 in / 8 in 203 mm / 203 mm
Shipping Weight 18.5 lb 8.4 kg
Specification K2-40 Published / Current Reference
ModelK2-40
Gage TypeDual Indicator Concentricity Gage
Carrier ConfigurationStandard Carrier + Vertical Carrier
Nominal Part Diameter3/4–4 in
Customer-Facing Metric Range20–102 mm
Current Parts-List Metric Class Reference20–105 mm
Maximum Part Length8 in / 203 mm
Approx. Overall Gage Length14.5 in / 368 mm
Approx. Gage Width8 in / 203 mm
Approx. Gage Height8 in / 203 mm
Published Shipping Weight18.5 lb / 8.4 kg
-40 Roller Selection

Select support geometry from the actual component.

Both K2-40 indicators reference the same supported rotational setup. Correct -40 roller and top-contact selection is therefore fundamental to the complete inspection system.

140-40FP · Full Plain Full plain main roller set for suitable large cylindrical support geometry.
140-40HP · Half Plain Half plain support where shoulders, transitions or nearby component geometry require additional clearance.
140-40QP · Quarter Plain Quarter plain support for narrower or more constrained cylindrical support lands.
Engineering rule: a 4-inch component diameter does not automatically determine the correct K2-40 roller set. Main roller geometry should be selected from the actual usable support surfaces on the component.

Evaluate cylindrical support-land width, adjacent shoulders, flange clearance, grooves, threads, splines, diameter transitions, support spacing, unsupported span, component stiffness and both indicator measurement locations.

Published -40 top roller reference: Universal Punch documentation identifies 230-40, approximately 1 × 5/16 in (25 × 8 mm), as the standard -40 top roller. Other published -40 top-contact sizes include 3/4 × 1/2 in, 7/8 × 1/2 in, 1 × 5/8 in, 1-1/8 × 5/8 in and 1-1/4 × 3/4 in configurations.
K2-40 dual indicator concentricity inspection architecture showing Standard Carrier and Vertical Carrier on the large capacity gage platform
K2-40 inspection architecture: two configurable measurement positions around one large-capacity supported rotational setup.
How K2-40 Is Configured

Confirm. Support. Position. Rotate. Interpret.

01
Confirm K2-40 capacity. Verify component diameter, length and usable support geometry against the -40 platform.
02
Select -40 main rollers. Configure stable support from the actual cylindrical support lands.
03
Configure the Standard Carrier. Position the first indicator from the drawing, datum relationship and measurement objective.
04
Configure the Vertical Carrier. Position the second indicator for vertical feature access.
05
Rotate the component. Use controlled rotation through the required inspection cycle.
06
Interpret both readings. Evaluate each indicator according to the applicable datum structure, tolerance and inspection method.
Both K2-40 indicators reference the same supported rotational setup, while each indicator may be configured for a different feature or measurement location.
Indicator Configuration

Configure each K2-40 measurement position independently.

The two indicators do not have to perform identical measurement roles. Each measurement position should be selected around its required feature, range, resolution, stylus and access direction.

Indicator 1 · Standard Carrier Define range, resolution, stylus reach, contact direction and primary measurement position.
Indicator 2 · Vertical Carrier Define range, resolution, vertical contact geometry, carrier location and larger-component clearances.
Calibration & accessories Specify mounts, fine adjustment, analog or digital preference and required calibration documentation.
Manual & Motorized Rotation

Select rotational control around the inspection workflow.

Standard Architecture

Manual Rotation

Universal Punch literature describes a manual timing-belt pulley system for smooth, controlled rotational inspection.

Main rollers, top contact, rotation, Standard Carrier and Vertical Carrier positions work together as one complete K2-40 inspection configuration.

Optional · Part No. 278-40

K2-40 Variable Speed Motor Assembly

Universal Punch publishes 278-40 as the K2-40 Variable Speed Motor Assembly with a published 19 in / 482 mm base plate.

Current motor-drive documentation identifies a 24 VDC · 0–10 rpm · variable-speed · forward/reverse architecture. Confirm transformer, foot-switch and current electrical accessories when quoting.

Ask About Motorizing the K2-40 →
Model Selection

Choose the large-capacity model from measurement access.

K2-40 vs. K1-40

Feature K2-40 K1-40
Indicator Positions22
Nominal Part Diameter3/4–4 in3/4–4 in
Maximum Part Length8 in / 203 mm8 in / 203 mm
Primary CarrierStandardStandard
Second CarrierVertical CarrierSide Carrier
Published Shipping Weight18.5 lb / 8.4 kg18.5 lb / 8.4 kg
K1-40 and K2-40 serve essentially the same large-capacity size class. Select between them primarily by the required direction of the second indicator: Side Carrier for K1-40 and Vertical Carrier for K2-40.

K2-40 vs. G2-40

K2-40

Dual Indicator

Standard Carrier + Vertical Carrier

Two configurable measurement positions around one large-capacity supported rotational setup.

G2-40

Vertical Carrier Architecture

One vertical-access measurement architecture

Choose when one Vertical Carrier inspection position is sufficient.

View G2-40 →

K2-40 vs. KK2-40

K2-40

2 Measurement Positions

Standard Carrier + Vertical Carrier.

Choose when Standard and Vertical access satisfy the inspection plan.

KK2-40

3 Measurement Positions

Standard Carrier + Side Carrier + Vertical Carrier.

Choose when the large component additionally requires an independent Side Carrier position.

View KK2-40 →

K2-Series Capacity Progression

Model Part Diameter Maximum Part Length Architecture
K2-10 1/8–1 in / 3–25 mm 4 in / 102 mm Standard + Vertical Carrier
K2-20 3/8–2 in / 10–50 mm 6 in / 152 mm Standard + Vertical Carrier
K2-40 3/4–4 in / 20–102 mm nominal 8 in / 203 mm Standard + Vertical Carrier
K2-Series definition: K2-10, K2-20 and K2-40 preserve the same Standard Carrier + Vertical Carrier dual-indicator architecture while increasing component capacity.
Universal Punch System Selection

Configure K2-40 around the complete inspection requirement.

The K2-40 is a configurable inspection system. Final application depends on gage selection, support geometry, both indicator positions, accuracy and calibration requirements, and rotational method.

1 · Select K2-40 Confirm the large -40 component envelope and Standard + Vertical Carrier dual-indicator architecture.
2 · Select support geometry Choose -40 main rollers and top contact from the actual support journals, clearances and measurement features.
3 · Configure both indicators Determine Standard and Vertical Carrier positions, indicator ranges, resolutions, styli, mounts and fine adjustment.
4 · Define accuracy & calibration Specify Standard Black requirements and the calibration or traceability documentation needed for the inspection plan.
5 · Select rotation Choose manual rotation or the optional 278-40 variable-speed motor package around the production workflow.
6 · Review the complete application Validate the setup from the component drawing rather than selecting accessories independently.
Manufacturer Configuration Support

Universal Punch can review the complete K2-40 application.

Large-component concentricity inspection involves more than selecting a 4-inch gage. The complete setup depends on support geometry, two measurement positions, indicator geometry, calibration requirements and rotational control.

Send the actual part drawing so the -40 support system, Standard Carrier position, Vertical Carrier position, indicators and drive architecture can be considered together.

Request a K2-40 Application Review →
Large-Capacity Model Confirm the component fits the K2-40 / -40 inspection envelope.
Support Geometry Configure 140-40 series rollers from the actual support lands.
Standard Carrier Define the primary measurement position from the drawing and tolerance.
Vertical Carrier Configure vertical access for the second inspection feature.
Standard Black Accuracy Specify the required measurement and calibration documentation for the -40 configuration.
Manual or Motorized Select rotational control around the actual production inspection workflow.
K2-40 Technical FAQ

Common engineering questions about the K2-40.

What is the Universal Punch K2-40?

The Universal Punch K2-40 is a large-capacity dual-indicator concentricity gage for cylindrical components from 3/4–4 in (20–102 mm nominal customer-facing range) in diameter and up to 8 in (203 mm) long. It combines a Standard Carrier with a Vertical Carrier so two configurable indicator positions can be arranged around one supported rotational setup.

What does K2-40 mean?

K2 identifies the Universal Punch dual-indicator architecture using a Standard Carrier plus Vertical Carrier. The -40 suffix identifies the large component class used for nominal 3/4–4 in cylindrical parts.

What size parts can the K2-40 inspect?

The customer-facing nominal K2-40 range is 3/4–4 in (approximately 20–102 mm) in diameter with part lengths up to 8 in (203 mm). Current parts documentation also references the -40 metric class as 20–105 mm. Confirm the actual component diameter and current production capability when quoting.

Why are both 20–102 mm and 20–105 mm associated with K2-40?

The nominal 3/4–4 in customer-facing range converts to approximately 20–102 mm, while current Universal Punch parts documentation uses a 20–105 mm metric class reference for the -40 platform. Both refer to the large -40 model family. Confirm the exact production envelope for the application when quoting.

What are the published overall dimensions of the K2-40?

Published K1/K2-40 general data lists approximately 14.5 in (368 mm) overall length, 8 in (203 mm) width and approximately 8 in (203 mm) height.

How much does the K2-40 weigh?

The published K2-40 shipping weight is 18.5 lb (8.4 kg).

Why does the K2-40 use two indicators?

K2-40 provides two configurable measurement-access positions around the same supported rotational setup. The first uses a Standard Carrier and the second uses a Vertical Carrier. What each indicator evaluates depends on the drawing, support geometry, datum structure and inspection method.

What is the difference between K2-40 and K1-40?

K2-40 and K1-40 share the large -40 capacity class and both use two indicator positions. K2-40 uses Standard plus Vertical Carrier architecture, while K1-40 uses Standard plus Side Carrier architecture. Select between them primarily by the required direction of the second indicator.

What is the difference between K2-40 and G2-40?

G2-40 uses a Vertical Carrier inspection architecture. K2-40 adds a Standard Carrier measurement position so two indicator positions can be configured around the same supported rotational setup.

What is the difference between K2-40 and KK2-40?

K2-40 uses Standard plus Vertical Carrier architecture for two measurement positions. KK2-40 adds an independent Side Carrier position, creating Standard plus Side plus Vertical Carrier measurement access.

What main roller configurations are published for K2-40?

Universal Punch publishes Full Plain 140-40FP, Half Plain 140-40HP and Quarter Plain 140-40QP main roller configurations for the -40 model class. Final support geometry should be selected from the actual usable cylindrical support lands on the component.

What is the standard -40 top roller?

Universal Punch documentation identifies 230-40, approximately 1 × 5/16 in (25 × 8 mm), as the standard -40 top roller. Other -40 top roller sizes are also published. Confirm final top-contact geometry against the actual component.

Is K2-40 a Precision Gold gage?

Current Universal Punch documentation identifies Precision Gold for applicable -10 and -20 model classes only. K2-40 is a -40 model and should therefore be represented under the Standard Black classification unless a different current production capability is specifically confirmed by Universal Punch.

What accuracy classification applies to K2-40?

Universal Punch publishes Standard Black at better than or equal to 4 µm (0.00016 in). Final performance and calibration documentation should be confirmed for the exact ordered K2-40 configuration.

Is the K2-40 NIST traceable?

Universal Punch documentation states that its Concentricity Gaging Systems are calibrated and directly traceable to N.I.S.T. Confirm the calibration certificate and documentation required for the ordered configuration.

Can the K2-40 be motorized?

Yes. Universal Punch publishes Part No. 278-40 as the K2-40 Variable Speed Motor Assembly with a published 19 in (482 mm) base plate. Confirm current electrical accessories and options when quoting.

What information should I send Universal Punch for a K2-40 quote?

Send the component drawing, maximum part diameter and length, usable support journals, support-land widths, shoulders, flanges, threads, splines or grooves, both measurement locations, required vertical access, datum relationship, tolerance, desired indicator resolution, calibration requirements and manual or motorized preference.

Configure the K2-40 Around Your Part

Send the drawing and both measurement locations.

Universal Punch can review the component geometry and inspection requirement to help determine K2-40 support geometry, Standard Carrier position, Vertical Carrier position, indicators, calibration documentation and rotational configuration.

  • component drawing or CAD print
  • maximum part diameter
  • overall part length
  • support-journal diameters
  • support-land widths
  • shoulders and flanges
  • threads, splines and grooves
  • measurement location #1
  • measurement location #2
  • required vertical indicator access
  • datum relationship
  • inspection tolerance
  • indicator resolution
  • calibration requirements
  • manual or motorized preference
  • production inspection volume
Request a K2-40 Quote → Explore Concentricity Gages

Compare K1-40, G2-40, KK2-40, and K2-20 when selecting measurement access and component capacity.