Universal Punch Concentricity Gaging System K1 Series · -40 Dual Indicator · Standard + Side Carrier

K1-40 Dual Indicator Concentricity Gage

Two configurable measurement positions for larger cylindrical components.

The Universal Punch K1-40 is a large-capacity dual-indicator concentricity gage designed for cylindrical parts from 3/4–4 in (20–102 mm) in diameter and up to 8 in (203 mm) long.

Its defining K1 architecture combines a Standard Carrier with a Side Carrier, providing two configurable indicator contact positions around the same supported rotating component.

Correct model selection depends not only on component size, but also on where the inspection features are located and how each indicator must approach the part.

Universal Punch K1-40 dual indicator concentricity gage with Standard Carrier and Side Carrier for 3/4 to 4 inch cylindrical parts
K1-40 · Dual Indicator Gage. Standard Carrier + Side Carrier architecture in the large -40 component class.
3/4–4 in 20–102 mm customer-facing part diameter
Up to 8 in 203 mm maximum part length
2 Indicators Standard + Side Carrier architecture
18.5 lb 8.4 kg published shipping weight
Technical page last updated: September 1, 2026. Current production configuration should be confirmed at quotation.
K1-40 Definition

The large -40 dual-indicator gage with Standard + Side Carrier access.

K1 identifies Universal Punch's dual-indicator architecture using a Standard Carrier plus Side Carrier.

-40 identifies the larger Universal Punch size class for customer-facing applications from 3/4–4 in / 20–102 mm in diameter.

The K1-40 is intended for larger cylindrical components where two indicator positions are useful around one supported rotational setup and the second measurement location benefits from lateral access.

The Universal Punch K1-40 is a dual-indicator concentricity gage for 3/4–4 in (20–102 mm) diameter cylindrical components up to 8 in (203 mm) long. It combines a Standard Carrier with a Side Carrier so two indicator positions can be configured around the same supported rotating component.
Full product view of Universal Punch K1-40 dual indicator concentricity gage
K1-40 architecture: large -40 support capacity with a Standard Carrier and lateral Side Carrier.
Dual-Indicator Architecture

Two indicators are valuable because they create two measurement-access positions.

The defining benefit of the K1-40 is not simply that two indicators are present. It is the ability to configure a Standard Carrier measurement position and a second lateral Side Carrier position around one rotational setup.

Measurement Position 1

Standard Carrier

Provides the primary configurable indicator position. Final contact location, stylus direction, range and resolution should be selected from the drawing and inspection plan.

Measurement Position 2

Side Carrier

Provides lateral access to the rotating component. This second carrier position is the defining measurement-access feature of the K1 architecture.

K1-40 does not inherently measure two predetermined characteristics. What each indicator evaluates is determined by the component drawing, datum structure, contact locations and inspection procedure.
Standard Carrier

The primary measurement position for the K1-40.

The Standard Carrier supports the first configurable indicator position around the rotating component. The final position should be derived from the actual print—not simply copied from a product photograph.

Inspection feature Identify the diameter, journal, face, shoulder or other rotational feature being evaluated.
Datum relationship Define what the indicator reading represents relative to the supported rotational axis.
Probe clearance Account for shoulders, flanges, grooves, threads, splines and nearby component geometry.
Indicator selection Choose range, resolution, stylus and approach direction from the tolerance and access requirement.
Configuration principle: the indicator arrangement shown in photography is an example. Final K1-40 measurement positioning should come from the actual component drawing and inspection objective.
K1-40 Standard Carrier primary indicator measurement position detail
K1-40 Standard Carrier detail. Configure the primary indicator around the actual inspection feature.
K1-40 Side Carrier lateral second indicator measurement position detail
K1-40 Side Carrier detail. Lateral access for the second measurement position defines the K1 architecture.
Side Carrier Architecture

Lateral access is the feature that separates K1-40 from K2-40.

The second K1-40 indicator is configured using a Side Carrier. This creates lateral measurement access to the supported component.

Choose K1-40 when the second indicator requires Side Carrier access. Choose K2-40 when the second indicator requires Vertical Carrier access.

Because both models occupy the same large -40 capacity class, the decisive difference is measurement access and carrier architecture, not diameter and length alone.

Published K1-40 General Data

Large -40 capacity with dual measurement access.

Use the customer-facing capacity below for model selection. Final roller, carrier, indicator, accuracy and drive configuration should be confirmed when quoting.

Part Diameter 3/4–4 in 20–102 mm
Part Length Up to 8 in 203 mm
Carrier Architecture Standard + Side Dual indicator
Overall Length 14.5 in 368 mm
Width / Approx. Height 8 in / 8 in 203 mm / 203 mm
Shipping Weight 18.5 lb 8.4 kg
Specification K1-40 Published Data
Model K1-40
Gage Type Dual Indicator Concentricity Gage
Carrier Configuration Standard Carrier + Side Carrier
Part Diameter 3/4–4 in / 20–102 mm
Maximum Part Length 8 in / 203 mm
Overall Gage Length 14.5 in / 368 mm
Gage Width 8 in / 203 mm
Approximate Height 8 in / 203 mm
Published Shipping Weight 18.5 lb / 8.4 kg
-40 Roller Selection

A larger gage does not remove the need for correct support geometry.

Both K1-40 indicator positions reference the same supported rotational setup. Stable component support is therefore fundamental to the measurement system.

140-40FP · Full Plain Full plain main roller set for suitable -40 cylindrical support geometry.
140-40HP · Half Plain Half plain support where shoulders or adjacent features require additional clearance.
140-40QP · Quarter Plain Quarter plain support geometry for narrower or more constrained cylindrical support lands.
Engineering rule: a 4-inch maximum component diameter does not automatically determine the correct roller set. Select K1-40 main roller geometry from the actual cylindrical support lands available on the part.

Evaluate journal diameter and width, shoulders, flanges, threads, splines, grooves, steps, diameter transitions, unsupported span, measurement location and component stiffness.

Current-vs-legacy documentation note: current Universal Punch parts documentation identifies 230-40, approximately 1 × 5/16 in (25 × 8 mm), as the standard -40 top roller. Historical literature has published other -40 top-contact configurations. Current production documentation and the actual component geometry should control final selection.
K1-40 dual indicator concentricity inspection architecture showing Standard Carrier and Side Carrier around one supported large cylindrical component
K1-40 inspection architecture: one supported rotational setup with two independently configurable measurement positions.
How the K1-40 Is Configured

Confirm. Support. Position. Rotate. Interpret.

01
Confirm the -40 inspection envelope. Verify component diameter, length and usable support surfaces against the K1-40 platform.
02
Select the main roller geometry. Choose stable -40 support geometry from the actual cylindrical lands.
03
Position the Standard Carrier indicator. Configure the first contact point from the drawing, datum relationship and required measurement.
04
Position the Side Carrier indicator. Configure lateral access for the second inspection location.
05
Rotate the supported component. Use controlled rotation through the required inspection cycle.
06
Interpret both indicator responses. Use the drawing, datum structure, tolerance and inspection method to interpret each measurement.
Both K1-40 indicators reference the same supported rotational setup, but each indicator can be positioned for a different inspection location.
Analog & Digital Indicator Configuration

Configure the two K1-40 measurement positions independently.

The two K1-40 indicators do not have to perform identical measurement roles. Each position should be configured around its individual inspection objective.

Indicator 1 · Standard Carrier Define resolution, range, stylus reach, contact direction and primary measurement position.
Indicator 2 · Side Carrier Define resolution, range, stylus geometry, lateral carrier location and second measurement position.
Calibration & accessories Specify mounts, extensions, fine adjustment, digital or analog preference, and required calibration documentation.
Manual & Motorized Rotation

Choose the rotational method around the inspection workflow.

Standard Architecture

Manual Rotation

Universal Punch literature describes a manual timing-belt pulley system for smooth, controlled rotational inspection.

Component support, top contact, rotation and both indicator positions work together as one K1-40 inspection configuration.

Optional · Part No. 277-40

K1-40 Variable Speed Motor Assembly

Universal Punch publishes 277-40 as the K1-40 Variable Speed Motor Assembly with a published 19 in / 482 mm base plate.

Current motor-drive documentation identifies a 24 VDC · 0–10 rpm · variable-speed · forward/reverse architecture. Confirm current transformer, foot-switch and electrical options when quoting.

Ask About Motorizing the K1-40 →
K1-40 Model Selection

Size identifies the platform. Carrier access identifies the architecture.

K1-40 vs. K2-40

Feature K1-40 K2-40
Indicator Positions 2 2
Part Diameter 3/4–4 in / 20–102 mm 3/4–4 in / 20–102 mm
Maximum Part Length 8 in / 203 mm 8 in / 203 mm
Primary Carrier Standard Standard
Second Carrier Side Carrier Vertical Carrier
Published Shipping Weight 18.5 lb / 8.4 kg 18.5 lb / 8.4 kg
Choose K1-40 when the second measurement requires lateral Side Carrier access. Choose K2-40 when the second measurement requires Vertical Carrier access. Because the models share the same published capacity envelope, carrier access—not part size alone—is the primary distinction.

K1-40 vs. G1-40

K1-40

Dual Indicator

Standard Carrier + Side Carrier

Two configurable measurement positions around the same supported large-part rotational setup.

G1-40

Side Checker

Side Carrier inspection architecture

Choose when one Side Carrier measurement position is sufficient.

View G1-40 →
Choose G1-40 when one Side Carrier inspection position is sufficient. Choose K1-40 when the application requires a Standard Carrier position plus a second lateral Side Carrier position.

K1-40 vs. KK1-40

K1-40

2 Measurement Positions

Standard Carrier + Side Carrier.

Choose when two configurable indicator positions satisfy the inspection plan.

KK1-40

3 Measurement Positions

Standard Carrier + Side Carrier + Side Carrier.

Choose when an additional independent lateral measurement position is required.

View KK1-40 →
Choose K1-40 when two indicator positions satisfy the inspection. Move to KK1-40 when the application requires a Standard Carrier plus two Side Carrier measurement positions.

K1-20 vs. K1-40

Feature K1-20 K1-40
Architecture Standard + Side Standard + Side
Part Diameter 3/8–2 in / 10–50 mm 3/4–4 in / 20–102 mm
Maximum Part Length 6 in / 152 mm 8 in / 203 mm
Overall Gage Length 12.5 in / 318 mm 14.5 in / 368 mm
Published Shipping Weight 14.8 lb / 6.8 kg 18.5 lb / 8.4 kg
K1-20 and K1-40 use the same Standard + Side Carrier concept. Choose K1-40 when the component requires the larger -40 support envelope.

K1-Series Capacity Progression

Model Part Diameter Maximum Part Length Architecture
K1-10 1/8–1 in / 3–25 mm 4 in / 102 mm Standard + Side Carrier
K1-20 3/8–2 in / 10–50 mm 6 in / 152 mm Standard + Side Carrier
K1-40 3/4–4 in / 20–102 mm 8 in / 203 mm Standard + Side Carrier
K1-Series definition: Universal Punch's K1 Series is its dual-indicator Standard Carrier + Side Carrier concentricity-gage family. K1-10, K1-20 and K1-40 retain the same measurement-access concept while increasing component capacity.
Universal Punch System Selection

Configure K1-40 in three engineering decisions.

Universal Punch's Concentricity Gaging System is best understood as a configurable inspection platform: select the model, select the component support, then configure the measurement hardware and rotation.

1 · Select K1-40 Choose K1-40 when the -40 component envelope and Standard + Side Carrier dual-indicator architecture match the application.
2 · Select support geometry Choose Full Plain, Half Plain, Quarter Plain or other appropriate support geometry from the actual component drawing.
3 · Configure both measurement positions Select indicators, styli, mounts, calibration requirements, accessories and manual or motorized rotation.
Manufacturer-Controlled K1-40 Reference

Why Universal Punch is the source for configuring the K1-40.

A useful K1-40 product page must explain more than a diameter range. The correct inspection system depends on component support, two measurement-access locations, indicator geometry, accuracy classification, calibration and rotational control.

Universal Punch defines the model family, support hardware, carrier architecture, indicators, accessories and drive options that make up the complete system. That manufacturer-controlled context is what distinguishes the K1-40 from a generic two-indicator fixture.

Review a K1-40 Application →
Model Selection Confirm the -40 capacity class and K1 carrier architecture.
Support Geometry Configure the roller system from the actual cylindrical support lands.
Standard Carrier Define the primary measurement position from the drawing and tolerance.
Side Carrier Configure lateral measurement access for the second inspection feature.
Accuracy & Calibration Define the correct -40 accuracy classification, indicators and traceability documentation.
Manual or Motorized Select rotational control around the actual production inspection workflow.
Technical Data Transparency

Current production information takes precedence over historical literature.

Universal Punch has decades of published concentricity-gage literature. Some legacy documents may contain older roller references, dimensional conventions or accessory configurations.

For K1-40 quoting and application engineering: use the current customer-facing -40 capacity, current production documentation and the actual component drawing. Where current and legacy references differ, the current production configuration should control.

This transparency is intentional. A manufacturer authority page should distinguish current production guidance from historical documentation rather than silently merging conflicting specifications.

K1-40 Technical FAQ

Common engineering questions about the K1-40.

What is the Universal Punch K1-40?

The Universal Punch K1-40 is a dual-indicator concentricity gage for cylindrical components from 3/4–4 in (20–102 mm) in diameter and up to 8 in (203 mm) long. It combines a Standard Carrier with a Side Carrier so two configurable indicator positions can be arranged around the same supported rotating component.

What does K1-40 mean?

K1 identifies the Universal Punch dual-indicator architecture using a Standard Carrier plus Side Carrier. The -40 suffix identifies the large 3/4–4 in (20–102 mm) component class.

What size parts can the K1-40 inspect?

The customer-facing published K1-40 capacity is 3/4–4 in (20–102 mm) in diameter with part lengths up to 8 in (203 mm).

What are the published overall dimensions of the K1-40?

Published Universal Punch general data for the K1/K2-40 platform lists approximately 14.5 in (368 mm) overall length, 8 in (203 mm) width and approximately 8 in (203 mm) height.

How much does the K1-40 weigh?

The published K1-40 shipping weight is 18.5 lb (8.4 kg).

Why does the K1-40 use two indicators?

The K1-40 provides two configurable measurement-access positions around the same supported rotational setup. The first uses the Standard Carrier and the second uses the Side Carrier. The actual characteristics being inspected depend on the drawing, datum structure, indicator locations and inspection method.

What is the difference between K1-40 and K2-40?

Both are large -40 dual-indicator gages with similar published capacity. K1-40 uses a Standard Carrier plus Side Carrier, while K2-40 uses a Standard Carrier plus Vertical Carrier. Choose the model from the required second-indicator access direction.

What is the difference between K1-40 and G1-40?

G1-40 is a Side Checker architecture using Side Carrier measurement access. K1-40 combines a Standard Carrier measurement position with an additional Side Carrier position for dual-indicator inspection.

What is the difference between K1-40 and KK1-40?

K1-40 provides two configurable indicator positions using Standard plus Side Carrier architecture. KK1-40 extends that concept to three measurement positions using a Standard Carrier plus two Side Carriers.

What main roller configurations are available for K1-40?

Universal Punch publishes Full Plain 140-40FP, Half Plain 140-40HP and Quarter Plain 140-40QP main roller configurations for the -40 model class. Final support geometry should be selected from the actual component drawing and usable cylindrical support lands.

What is the standard -40 top roller?

Current Universal Punch parts documentation identifies 230-40, approximately 1 × 5/16 in (25 × 8 mm), as the current standard -40 top roller. Historical documentation has published other -40 top-contact configurations, so final production configuration should be confirmed when quoting.

Is K1-40 Precision Gold eligible?

Current Universal Punch documentation identifies Precision Gold for applicable -10 and -20 model classes. K1-40 is a -40 model, so it should not be represented as a Precision Gold model without a specific current engineering confirmation.

What accuracy does Universal Punch publish for K1-40?

Universal Punch publishes its Standard Black concentricity-gage classification as better than or equal to 4 µm (0.00016 in). Final accuracy, indicators and calibration documentation should be confirmed for the exact ordered K1-40 configuration.

Is the K1-40 NIST traceable?

Universal Punch documentation states that its Concentricity Gaging Systems are calibrated and directly traceable to N.I.S.T. Confirm the specific calibration certificate and documentation required for the ordered configuration.

Can the K1-40 be motorized?

Yes. Universal Punch publishes Part No. 277-40 as the K1-40 Variable Speed Motor Assembly with a published 19 in (482 mm) base plate. Confirm the current electrical package and accessories when quoting.

What does the K1-40 measure?

The K1-40 does not inherently define two fixed measurement characteristics. What each indicator evaluates is determined by the component support, indicator contact locations, datum structure, tolerance and inspection procedure.

What information should I send Universal Punch for a K1-40 quote?

Send the component drawing, maximum part diameter and length, usable support journals, support-land widths, shoulders, flanges, threads or grooves, both measurement locations, datum relationship, tolerance, desired indicator resolution, calibration requirements and manual or motorized preference.

Configure the K1-40 Around Your Part

Send the drawing and both measurement locations.

Universal Punch can use the actual component geometry and inspection requirement to help determine the appropriate K1-40 roller support, Standard Carrier position, Side Carrier position, indicators, calibration documentation and manual or motorized rotational configuration.

  • component drawing or CAD print
  • maximum part diameter
  • overall part length
  • usable cylindrical support journals
  • support-land widths
  • shoulders and flanges
  • threads, splines and grooves
  • measurement location #1
  • measurement location #2
  • datum relationship
  • tolerance / indicator resolution
  • calibration requirements
  • manual or motorized preference
  • production inspection requirements
Request a K1-40 Quote → Explore Concentricity Gages

Compare K1-20, K2-40, G1-40, and KK1-40 when selecting component capacity, measurement access and number of indicator positions.