G2-40 Side Checker Concentricity Gage
Vertical Carrier inspection access for larger cylindrical components from 3/4–4 in diameter.
The Universal Punch G2-40 is the largest size class in the G2 Side Checker family. Its defining feature is the Vertical Carrier, which provides indicator access from above for inspection features best accessed from above the supported component.
Universal Punch source documentation consistently publishes a 3/4–4 in diameter class, part lengths up to 8 in (203 mm), and an 11.2 lb (5.1 kg) shipping weight.
The largest Vertical Carrier configuration in the G2 family.
The G2 family uses a common inspection architecture: Side Checker Gage + Vertical Carrier. The model suffix determines the size class. G2-40 extends that architecture to the large -40 inspection platform.
The Universal Punch G2-40 is a -40 Side Checker concentricity gage with a Vertical Carrier for larger cylindrical components. The consistently published inch diameter range is 3/4–4 in, with part lengths up to 8 in (203 mm). The system is configured around the selected gage model, main rollers, indicator system and required accessories.
Position the measurement indicator above the inspection feature.
The Vertical Carrier positions the measurement indicator vertically above the supported component, giving the indicator and stylus an overhead approach to the inspection feature. Final carrier position, stylus reach, contact direction and clearance should be selected from the actual drawing and inspection requirement.
Verify part diameter, length and usable support surfaces before selecting the final configuration.
Select surfaces that can support stable rotational inspection on the chosen main rollers.
Configure indicator position, stylus reach and measurement direction around the actual feature.
Select indicator style, range, resolution, stylus, mounts and manual or motorized rotation around the actual print.
A single technical reference for the G2-40 platform.
| Model | G2-40 |
|---|---|
| Gage Type | Side Checker Gage |
| Carrier | Vertical Carrier |
| Published Inch Diameter Range | 3/4–4 in |
| Published Part Length | 0.25–8 in / 6.3–203 mm general-data range |
| Gage Length | 14.5 in / 368 mm |
| Gage Width | 6 in / 152 mm |
| Gage Height | Approx. 8 in / 203 mm |
| Shipping Weight | 11.2 lb / 5.1 kg |
| Published -40 Support Pressure | 32 lb / 4.4 Nm |
Select support geometry from the component, not from diameter alone.
Current Universal Punch parts documentation publishes three primary main-roller styles for the -40 model class. Final selection depends on the component's support lands, adjacent geometry and required inspection clearance.
| Top Roller | Published Size | Current Parts-List Note |
|---|---|---|
| 210-40 | 3/4 × 1/2 in · 19 × 12 mm | Published -40 option |
| 221-40 | 7/8 × 1/2 in · 22 × 12 mm | Published -40 option |
| 230-40 | 1 × 5/16 in · 25 × 8 mm | Current standard |
| 233-40 | 1 × 5/8 in · 25 × 16 mm | Published -40 option |
| 231-40 | 1-1/8 × 5/8 in · 28 × 16 mm | Published -40 option |
| 232-40 | 1-1/4 × 3/4 in · 32 × 19 mm | Published -40 option |
The readout is part of the gage specification.
Universal Punch defines the Concentricity Gaging System around three primary selections: gage model, main rollers, and indicator(s) / accessories. Current parts documentation includes analog and digital indicators, multiple mounts, swivel supports and dedicated -40 carrier components.
Publish the accuracy class that applies to the -40 model family.
Standard Black
Current Universal Punch parts documentation identifies Standard Black at ≤4 µm and describes the gage classifications as calibrated and directly traceable to NIST.
Precision Gold
The G2-40 page should therefore publish Standard Black unless Universal Punch engineering specifically confirms a current custom or exception configuration.
Dedicated -40 drive components support rotational inspection.
Current Universal Punch parts documentation lists dedicated Timing Belt Sets for Model -40 and a Complete Drive System for Model -40 consisting of belts, pulleys, drive knob and pin.
A dedicated G2-40 variable-speed motor assembly is currently published.
Current Universal Punch parts documentation lists a Part No. 273-40 — G2-40 Variable Speed Motor Assembly with a 19 in / 482 mm base plate. The current drive-system section identifies 24 VDC / 0–10 rpm, forward/reverse control and 110/220 VAC transformer support.
Same -40 capacity class. Different indicator-access architecture.
G1-40
Choose G1-40 when lateral indicator access from the side best reaches the required inspection feature.
G2-40
Choose G2-40 when indicator access from above better matches the inspection feature, stylus direction and available clearance.
One Vertical Carrier architecture across three size classes.
| Model | Published / Selection Diameter Class | Part Length | Carrier | Shipping Weight |
|---|---|---|---|---|
| G2-10 | 1/8–1 in / 3–25 mm class | Up to 4 in / 102 mm | Vertical Carrier | 4.9 lb / 2.2 kg |
| G2-20 | 3/8–2 in / 10–50 mm class | Up to 6 in / 152 mm | Vertical Carrier | 6.4 lb / 2.9 kg |
| G2-40 | 3/4–4 in / current 20–105 mm selection class | Up to 8 in / 203 mm | Vertical Carrier | 11.2 lb / 5.1 kg |
Manufacturer-controlled information for the G2-40 configuration.
The strongest reference for a production G2-40 is the combination of current Universal Punch model-selection, parts, accessory, general-data and calibration documentation together with the actual customer drawing. This page distinguishes current part-system information from historical catalog references where those sources differ.
Current model-selection documentation identifies G2-40 as the -40 Vertical Carrier configuration.
Current parts documentation identifies Full Plain, Half Plain and Quarter Plain -40 main-roller sets.
Identified as the standard top roller for the -40 model class.
Precision Gold is published for -10 / -20 model classes only in the current parts documentation.
19 in / 482 mm base plate with the current 24 VDC / 0–10 rpm variable-speed drive architecture.
Questions engineers, inspectors and buyers ask before specifying a G2-40.
The drawing—not the product photograph—determines the final configuration.
Send Universal Punch the part drawing, diameter, overall length, available cylindrical support lands, feature being inspected, measurement direction, Vertical Carrier clearance, tolerance, preferred indicator/readout, required resolution, manual or motorized rotation preference, and calibration requirements.