Skip to model selection
Universal Punch Concentricity Gaging System

Concentricity Gages & Rotational Inspection Systems

Compare Universal Punch systems by inspection application, part diameter, length, carrier arrangement, support geometry, indicator positions and rotation method.

Manufacturer guidance: model capacity is only the starting point. Final rollers, support locations, measurement access and indicator or Lazer configuration must be selected from the part and inspection requirement.

Universal Punch A-10 concentricity gage configuration Basic
Universal Punch KK2-20 concentricity gage configuration Triple indicator
Universal Punch LGM-20 concentricity gage configuration Motorized Lazer
-10 / -20 / -40Common diameter classes across multiple architectures
Up to 24 inPublished part length in extended HL shaft configurations
≤4 μmPublished Standard Black system classification
≤2 μmPublished Precision Gold class for applicable -10 and -20 configurations
Start here

Find the right starting model without learning the catalog first.

Use the known-model search when you already have a part number. Otherwise, describe the application and the selector will narrow the complete directory. Results are starting recommendations; engineering confirmation remains part of final configuration.

I know the model

Go directly to it.

Enter a model such as A-10, G2-20, KK2-40 or LGM-20.

Help me choose

Start with the inspection.

Select what you need the gage to do. Leave any uncertain field set to “Not sure.”

Capacity does not confirm support suitability. Submit the part drawing so usable support lands, feature access, rollers and datum structure can be reviewed.

Family comparison

Choose the architecture before the size.

Several models share the same diameter envelope while using different carriers, indicator positions and inspection layouts. Start with the job the gage must perform.

View the complete technical family comparison
FamilyBest starting useCarrier / measurement architecturePositionsBrowse
A SeriesCompact general rotational inspectionStandard1
B SeriesGeneral cylindrical rotational inspectionStandard1
E SeriesEccentric or offset-journal checkingVertical roller1
F SeriesFastener recess inspectionRecess checking1
G1 SeriesMeasurement access from the sideSide1
G2 SeriesMeasurement access from above or verticallyVertical1
H SeriesLong cylindrical parts up to 12 inchesVertical1
HL SeriesExtended cylindrical parts up to 24 inchesVertical1
J SeriesLow-profile, surface-plate and comparator setupsComparator configuration1
K1 SeriesTwo measurement positions with lateral accessStandard + Side2
K2 SeriesTwo measurement positions with vertical accessStandard + Vertical2
KK1 SeriesThree measurement positions with two lateral positionsStandard + Two Side3
KK2 SeriesThree measurement positions with lateral and vertical accessStandard + Side + Vertical3
LG SeriesSteel-base Lazer measurement configurationLazer headLazer
LGM SeriesPowered rotation with Lazer measurement architectureLazer headLazer
Complete model directory

Compare every model in one place.

Search by model, application, carrier arrangement, diameter, part length, indicator count or drive. Every model remains present in crawlable page content even when the interactive filters narrow the visible results.

40 models shown
Configuration sequence: choose the inspection architecture, confirm the size class, select main rollers and top contact, then define the indicator or Lazer system, accessories, accuracy documentation and rotation method.
No models match the current selections. Clear one or more filters, or send the component drawing for application review.

A Series

Basic Single Gage · Standard Carrier

Compact general rotational inspection. Final support and measurement geometry is application dependent.

B Series

Basic Extended Gage · Standard Carrier

General cylindrical rotational inspection. Final support and measurement geometry is application dependent.

B-10

-10
Basic Extended Gage · Standard Carrier
Universal Punch B-10 concentricity gage

General cylindrical rotational inspection

Part diameter1/8–1 in
3–25 mm
Part lengthUp to 4 in
102 mm
StandardPositions: 1Manual
3/32 in capacity with Zero Style Rollers

B-20

-20
Basic Extended Gage · Standard Carrier
Universal Punch B-20 concentricity gage

General cylindrical rotational inspection

Part diameter3/8–2 in
10–50 mm
Part lengthUp to 6 in
152 mm
StandardPositions: 1Manual

B-40

-40
Basic Extended Gage · Standard Carrier

General cylindrical rotational inspection

Part diameter3/4–4 in
20–102 mm
Part lengthUp to 8 in
203 mm
StandardPositions: 1Manual
Direct technical answer

What a concentricity gage actually does.

A Universal Punch concentricity gage supports a cylindrical component on controlled contact geometry, rotates the component and allows one or more indicators—or a configured Lazer system—to observe dimensional variation at selected features.

The measured variation is meaningful only in relation to the support condition, datum structure, probe direction, measurement location and inspection procedure. Diameter capacity alone does not establish the correct model or support geometry.

Plain-language definition

Concentricity gage: a precision rotational-inspection platform configured to support and rotate a cylindrical component while dimensional variation is observed at a defined feature.

SupportEstablish the intended rotational reference on selected component lands.
RotateTurn the supported component manually or with the specified drive method.
ObserveRead dimensional variation at the configured feature and probe direction.

What is TIR?

Total indicator reading is commonly the difference between the highest and lowest observed values through the specified rotation. Its interpretation depends on the setup and characteristic.

Is TIR the same as concentricity?

No. A variable indicator reading does not automatically prove the GD&T concentricity characteristic. The inspection method must match the drawing requirement.

Why do support lands matter?

The selected rollers establish the supported rotational reference. Shoulders, grooves, threads, transitions and insufficient land width can change support suitability.

Why use multiple indicators?

K and KK configurations provide two or three independently configurable contact positions. They do not permanently assign universal characteristics to those positions.

How to specify a system

Configure the system in four decisions.

Universal Punch selection documentation separates the gage model, main rollers, measurement equipment and accessories. A customer-facing workflow begins with the inspection architecture and part envelope.

01

Inspection architecture

Define the feature, datum relationship, probe access and number of measurement positions.

02

Part envelope

Confirm diameter, length, support-journal sizes, usable land widths and component stiffness.

03

Support geometry

Select main rollers and top contact around shoulders, threads, grooves and transitions.

04

Measurement and drive

Specify indicators or Lazer equipment, resolution, calibration documentation and rotation method.

Main rollers & top contact

Support geometry is part of the measurement system.

Choose roller geometry from the actual usable support surfaces—not nominal diameter alone. Preserve clearance around shoulders, threads, splines, grooves and the feature being inspected.

Full PlainBroad support geometry across published 110FP, 120FP and 140FP families.
Half PlainReduced-width support geometry across published 110HP, 120HP and 140HP families.
Quarter PlainNarrower support geometry across published 110QP, 120QP and 140QP families.
Zero StylePublished -10 configurations for very small diameters or difficult access conditions.
Top ContactTop-roller size and contact geometry must match the selected component support condition.
Special RollersApplication-specific geometry may be evaluated when standard rollers do not fit the part.
Accuracy, indicators & drive

Model size is only part of the specification.

Confirm the selected model’s current classification, indicator or Lazer equipment, calibration documentation and complete application setup during quotation.

Standard Black≤4 μm

Published system classification. Confirm the selected model and documentation requirement.

Precision Gold≤2 μm

Published for applicable -10 and -20 configurations. Do not assume eligibility for every model.

MeasurementIndicator / Lazer

Range, resolution, stylus or head position and output must match the inspection requirement.

RotationManual / Motorized

Selected standard models may be configured with a drive; LGM identifies a dedicated motorized Lazer family.

Engineering knowledge center

Answers that improve the inspection—not just the purchase.

These topics form the technical foundation for model selection, setup development and responsible interpretation of rotational measurement results.

Measurement fundamentals

Concentricity vs runout

Understand why a rotational indicator reading and the GD&T concentricity characteristic are not automatically interchangeable.

Reading interpretation

Understanding TIR

Relate maximum-to-minimum indicator movement to the specified datum, feature and inspection procedure.

Support geometry

Selecting roller contacts

Compare Full, Half, Quarter, Zero Style and application-specific support geometry.

Measurement access

Carrier arrangements

Use Standard, Side, Vertical and multi-carrier layouts to reach the required features.

Inspection workflow

Manual vs motorized rotation

Choose rotation based on component control, inspection volume and measurement process requirements.

Quality system

Calibration and traceability

Review Universal Punch quality and calibration support, then specify required documentation with the quotation.

Engineering FAQ

Common concentricity gage questions.

These direct answers support initial selection. Final configuration should be reviewed from the actual component and inspection requirement.

What is a concentricity gage?

A concentricity gage supports a cylindrical component on controlled roller contacts and rotates the part while one or more indicators or a configured measurement system monitors dimensional variation. The setup and inspection method determine how the observed variation should be interpreted.

What does a concentricity gage measure?

It observes dimensional variation at a selected feature while the component rotates about the support condition established by the gage. The reading may support runout or concentricity-related inspection when the datum, contact locations and procedure match the drawing requirement.

Does the displayed reading automatically prove GD&T concentricity?

No. A variable indicator reading is not automatically equivalent to the GD&T concentricity characteristic. Interpretation depends on the datum structure, support geometry, measurement location, probe direction and approved inspection method.

What is TIR?

TIR commonly refers to total indicator reading: the difference between the highest and lowest observed indicator values through the specified rotation. Its meaning depends on the setup and characteristic being evaluated.

How do I choose the correct Universal Punch model?

Start with the inspection application and required measurement access. Then confirm part diameter, length, support surfaces, roller geometry, indicator positions, accuracy requirement and rotation method. Universal Punch can review the component drawing before the final configuration is specified.

What do -10, -20 and -40 mean?

They identify common diameter classes used across multiple Universal Punch families. -10 models commonly cover 1/8 to 1 inch, -20 models 3/8 to 2 inches and -40 models 3/4 to 4 inches. Exact length and architecture depend on the selected family.

What roller configurations are available?

Published main-roller families include Full Plain, Half Plain and Quarter Plain configurations. The -10 family also includes Zero Style options, and special roller geometry may be configured for difficult support surfaces.

What accuracy classifications are published?

Universal Punch documentation identifies Standard Black at 4 micrometers or better and Precision Gold at 2 micrometers or better for applicable -10 and -20 configurations. LG literature separately identifies a catalog accuracy statement. Confirm current model eligibility and calibration documentation when ordering.

Can a concentricity gage be motorized?

Manual rotation is used across standard configurations, while selected models can be configured with motorized drives. LGM identifies the dedicated motorized Lazer family. Rotation requirements should be confirmed during application review.

What should I submit for an application review?

Send the component drawing, diameter, length, usable support lands, feature being inspected, datum structure, measurement location, tolerance, desired indicator or Lazer configuration, rotation preference and calibration-documentation requirements.

Application review

Send the drawing before you guess.

Provide the component drawing, diameter, length, usable support lands, datum structure, feature location, tolerance, measurement positions, rotation preference and calibration-documentation requirements. Universal Punch can help identify the appropriate starting model and configuration.

Technical content should be reviewed against current production documentation before publication and whenever catalog or parts-list data changes.